Pressure Fit Post Systems

$4,995.00$11,320.00

Clear

The Handicare Pressure Fit System can be assembled in minutes, making it a great choice for both temporary and permanent portable solutions. The Pressure Fit track exerts equal pressure between the floor and ceiling to stabilize the unit while ensuring ceilings aren’t damaged. It also has a bath adapter that enables safe transfers into standard bathing systems. Available in two, three and four-post designs.

*Freight Cost is included in the cost of the product.*

Pressure Fit Post Systems

$4,995.00$11,320.00

The Handicare Pressure Fit System can be assembled in minutes, making it a great choice for both temporary and permanent portable solutions. The Pressure Fit track exerts equal pressure between the floor and ceiling to stabilize the unit while ensuring ceilings aren’t damaged. It also has a bath adapter that enables safe transfers into standard bathing systems. Available in two, three and four-post designs.

*Freight Cost is included in the cost of the product.*

Clear

Below are multiple .pdf files explaining in detail more information about the pressure fit post systems.

Additional information

Choose Post Number

2, 3, 4

Reviews

There are no reviews yet.

Be the first to review “Pressure Fit Post Systems”

Your email address will not be published. Required fields are marked *

Pressure Fit Brochure #1
Pressure Fit Brochure #2
Pressure Fit Track Dimensions Prism Handicare
Pressure Fit Two Post System Prism User Manual & Handicare
Pressure Fit Three Post System Prism User Manual & Handicare
Pressure Fit Four Post System Prism User Manual & Handicare

Overview of the Pressure Fit System

The Pressure Fit System is a lifting aid used by health care professionals and those providing care in the home to lift, position and transfer clients or a disabled family member. The Pressure Fit System is part of what is termed overhead lift technology which takes advantage of lifting from above and not from below or the side.The Pressure Fit System makes it possible to move mobility impaired individuals with minimal strain or risk to the caregiver, while providing complete safety, dignity and comfort for the client or family member.

The Pressure Fit System is designed to work with a Waverley Glen portable lift system such as the P-440. Use of other portable lift units with this system may be possible.

The Pressure Fit System can be used to lift and transfer individuals from a bed, chair or similar fixture. The
length is adjustable and thus can be assembled to suit a wide range of applications. The Pressure Fit System is easy to assemble and can be completed by just one person in a short period of time. Additionally, no tools are required. It is also light in weight and once dismantled, can be moved to another location such as a hotel or cottage.

Specifications of the Pressure Fit System

=

High-strength lightweight Aluminum

=

Portable or semi-permanent installation

=

Eliminates the mounting of a connection system in the ceiling

=

Pressure gauge indicator to help ensure proper installation

=

Quick attachment with secure fixings

=

Addresses a number of different bedroom & bathroom situations

=

Weight capacity 440 lbs

=

Adjustable in length & Built-in easy-slide trolley

=

Exerting pressure between Floor and Ceiling is 80 to 100 lbs.

=

Specially designed and engineered rubber molded feet for ultimate grip

=

Leveling indicators on posts

Completed Pressure Fit System

Ceiling Requirement

=

Install the Pressure fit system to a rigid ceiling structure.

=

Ceiling structure must have joists that are spanned maximum up to 24” between the trusses

=

Ceiling made of wood must be at least 12.7mm / 1/2” thickness.

=

Ensure the ceiling structure is not suspended by wires or rods.

=

Ensure ceiling should be clear of any cracks, grease, water or any other slippery substance.

Floor Requirement

=

Ensure Floor area is cleaned and free of dirt & debris.

=

Floor should meet the requirements of building code standards

=

Floor must not have a slope of more than .5 degree

Cautions: Before installation

– The pressure fit system parts should not be loose, broken or bend. If any part is missing or damaged do not install. Contact your local authorized dealer immediately.

– The Pressure Fit System must be assembled prior to use. Should you have any questions during assembly contact your local authorised dealer.

– Never installed the Bottom foot plate on the top portion of post section or vice versa. See section “Assembly” instructions.

– Ensure rubber feet are cleaned and dry prior to each use. See section “ General Inspection and maintenance”.

– Do not install The pressure Fit System to suspended ceiling.

– Do not install The pressure Fit System on a plaster ceiling.

– Do not install on a sloped floor greater than .5 degree.

– Ensure floor area is clear off dirt and debris.

– Never expose the Pressure Fit directly to water. Warranty does not cover any misuse or abuse of the Pressure Fit system.

– Any accessories used with the Pressure Fit System including lift and sling (s), should be checked to ensure that they are in good working order. Check for signs of wear or fraying prior to use. Report any unusual wear or damage immediately to your local authorised dealer.

– Ensure that a clear space is maintained around the Pressure Fit System. Remove all furniture and other obstacles out of the way before performing a transfer.

Cautions: After Installation

– Ensure that the pressure gauge is in the safe zone during set up.

– Ensure Posts are level both visually and with the built-in level. If unsure, use a master level to verify the straightness of the Posts.

– Make sure track is sitting properly on the posts.

– Make sure the trolley is sliding smoothly on the track.

– Make sure the safety lock button and level are locked.

– Never unlock the Post when Track is attached.

– Do not under any circumstance exceed the maximum load rating for this piece of equipment. Refer to the “Specifications” section of this manual.

– The installation of the Pressure Fit System, lift, accessories, and sling are certified to a maximum load. Do not exceed the maximum rated load of any of the components.

– The Pressure Fit System has been designed to lift vertically at its maximum load and at its maximum height. Do not attempt to lift an individual at an angle to the track.

– The Pressure Fit System and associated lift, and sling(s) are intended only for lifting and transferring of a person. Waverley Glen will not be responsible for any damage caused by the misuse, neglect or purposeful destruction of the lift and/or its’ associated components.

– Under no circumstance should the track, lift and sling (s) or entire system be put in control of a person who has not been properly trained in the use and care of this equipment. Failure to adhere to this warning may result in serious injury to the operator, and/or the individual being lifted/transferred.

– In places where more than one operator will be responsible for using the Pressure Fit, associated lift and sling(s), it is imperative that all operators be trained in its’ proper use.

– The Pressure Fit System and associated lift and sling (s) are not toys. Do not use them for unsafe practices. Do not allow children to play with this equipment or any of its components.

– To maintain optimum function, the Pressure Fit should be inspected and maintained on a regular basis.

– The manufacturer’s warranty is void if persons unauthorized by Waverley Glen perform work on the Pressure Fit System.